DINTEK Cat6 U/UTP 23AWG LSZH Cable 305M | 1101-04046:
DINTEK PowerMAX500TM unshielded Cat.6 / Class E U/UTP LSZH cable is guaranteed to exceed Cat.6 specifications as set down in ANSI/TIA and ISO/IEC standards. Our PowerMAX500TM solution comprises unshielded Cat. 6-component compliant patch panels, keystones, and patch cords.
When combined with DINTEK’s unshielded Cat.6 / Class E U/UTP LSZH cable, an end-to-end channel exists that maximizes data throughput and provides headroom for future technologies operating to, and beyond Gigabit Ethernet.
- Horizontal and backbone cable
- 1000BASE-TX Gigabit Ethernet / 1000BASE-T Gigabit Ethernet
- 100BASE-TX Fast Ethernet / 10BASE-TX Ethernet
- 100 Mbps TP-PMD / 100VG-AnyLAN
- Broadband Video / Voice / T1 / ISDN
- 10Gbit (500Mhz) Transmission up to a length of 70Mtrs
- Performance – ANSI/TIA 568.2-D Cat.6 / ISO/IEC 11801
- Structural – EN 13501-6:2014 | IEC 61156-5 | EN 50288-6-1
- PoE capability – IEEE 802.3bt level 3 & 4 (PoE++ & 4PPoE)
- Environmental – Conforms to RoHS and REACH Directives
- Flame testing – EN 60332-1-2 | EN61034-2 | EN 60754-1/2
Independent Certification
- ETL Certification according to ANSI / TIA-568.2-D Cat.6
- CPR Reaction To Fire Classification – Dca,s2,d2,a1 as per EN 50399
- Capable of handling the latest versions of Power over Ethernet
- Conductor sizes for PowerMAX500TM Cat.6 set at 23AWG
- LSZH jacketed 4-pair telecommunications cable
- Successful transmission at 500Mhz up to a length of 70Mtrs
- EZI-Pull 305Mtr Box for trouble-free installation
| Conductor |
| Material |
Pure Annealed Copper |
| Wire Size |
23AWG |
| Strand Type |
Solid Core |
| No. Of Pairs |
4P |
| Insulation |
| Material |
Polyethylene |
| Thickness |
0.21mm ± 0.01mm |
| Diameter |
0.98mm ± 0.05mm |
| Colors |
Blue/White | Orange/White | Green/White | Brown/White |
| Pair Foil Wrap |
None |
| Jacket |
| Material |
LSZH |
| Thickness |
0.5 mm ± 0.05mm |
| Diameter |
5.70mm ± 0.3mm |
| Color |
Gray |
| CPR Reaction To Fire Classification |
Dca,s2,d2,a1 |
| Foil Shield |
None |
| Braided Shield |
None |
| Physical Ranges |
| Jacket |
| Cold Bend Test |
-20 ± 2°C x 4hrs no crack |
| Min. Bending Radius |
Min. 4 x Cable Diameter |
| Max. Pulling Tension |
110N |
| Installation Temperature |
0℃ to +50℃ |
| Operating Temperature |
-20℃ to +60℃ |
| Electrical |
| Conductor Resistance |
Max. 9.38 Ω/100m at 20°C |
| DC Resistance Unbalance |
Max. 2% at 20°C |
| Pair-to-Ground Capacitance Unbalance |
Max. 1600 pF/km at 1 kHz |
| Dielectric Strength of Insulation |
DC 1.0 KV for 1 min |
| Insulation Resistance Test (500V) |
Min. 5000 MΩ/Km at 20°C |
| Mutual Capacitance |
Max. 5600 pF/100m at 1 kHz |
| Impedance 1 ~ 250Mhz |
100Ω ± 5% |
| Nominal Velocity Of Propagation |
67% |